Skip to content

Nudo FiberLite® FRP

FiberLite FRP Technical Data Class C - Pages 1 - 2 Class A - Pages 3 - 4 NUDO FiberLite FRP Technical Data 3004N.C _____________________________________________________________ Rev. 11 813 NUDO FiberLite FRP Class C Embossed and Smooth Wall Ceiling Panels NUDO FiberLite FRP panels are solid sheets composed of fiberglass and calcium carbonatefilled polyester resin. An embossed panel designed for interior wall finishes where washable durable panels are needed. NUDO FiberLite FRP is a durable flexible building wall material that is resistant to mold mildew and corrosion. The panel has a Class C rating for flame spread and smoke development when tested per ASTM E-84. Physical Properties Table 1 Typical Value Property .09 Flexural Strength Flexural Modulus Tensile Strength Tensile Modulus Elongation Water Absorption Izod Impact Coefficient of Linear Thermal Expansion Barcol Hardness Specific Gravity Abrasive Resistance Flash Ignition Temperature Self Ignition Temperature Flame Spread Index Smoke Generation Surface Burn Test 17000 5 6.0 x 10 8000 5 9.43 x 10 1.20 0.17 7.0 2.22 x 10 LP-S9 Smooth LP-F9-CT Embossed LP-S9-CT Smooth LP-F10-CT Embossed LP-S10-CT Smooth LP-F120-CT Embossed LP-S12-CT Smooth -5 30 1.6138 0.293 430 450 200 450 Class C Physical Properties Table 2 Part Number Nominal Panel Identifier Thickness LP-F9 Embossed Measure Test Method psi psi psi psi 72 hrs 21C Ft-lbsin ASTM D790 ASTM D790 ASTM D638 ASTM D638 ASTM D638 ASTM D570 ASTM D256 50 Humidity Temp -23C ASTM D696 Average NA weight loss Fahrenheit Fahrenheit Unit NA Unit NA Class C ASTM D2583 ASTM D792 TABER ASTM D1929 ASTM D1929 ASTM E84 ASTM E84 ASTM E84 Nominal Panel Weight Color Size .65 psf Almond Beige Black Blue Bordeaux Brown Ivory Silver Khaki Pearl Red White Med Gray Dark Gray Pineapple 4 x 8 10 Non-standard sizes available made-to-order. .090 .65 psf Almond Pearl White Black 4 x 8 10 .090 .65 psf Almond Ivory Pearl Beige Silver White 2x2 4 .10 .75 psf White 2x2 4 .120 1.0 psf White

2x2 4 .090 Form 3004N.C Rev. 11 813 SPECIFICATIONS The NUDO FiberLite FRP panels are manufactured with state-of-the-art laminating equipment and adhesives. COMPOSITION 2. Fiberglass and calcium carbonate-filled polyester resin. FINISHED PANEL QUALITY 6. The front side shall be embossed with a pebble type finish embossed finished or the panels shall have a wear side with a smooth finish smooth. Colors shall be throughout the panel and manufactured as specified. 7. The backside shall be smooth. Backside imperfections which do not affect functional properties are not cause for rejection. 8. Physical properties shall be set forth in Table 1. 9. Product quality standards and tolerance for panel weight and thickness shall be set for in Nudo Product Inc. Quality Control ProceduresStandards which are available upon request. 10. Dimensions shall be specified on purchased order subject to the following tolerances Width 18 3.2mm Length 18 3.2 mm Squareness not more than 18 3.2 mm out of square. 5. Panels shall be installed in accordance with the manufacturers guidelines as set forth in the installation guide. CERTIFICATION 2. Meets the minimum requirements of the major model building codes for Class C interior wall finishes. Flame spread of less than 200 smoke development less than 450 per ASTM E-84. FABRICATING RECOMMENDATIONS Note Protect your eyes with goggles cover your nose and FRP panels. When mouth with a filter mask when cutting FiberLite cutting FiberLite FRP position the panel so that the saw blade enters the decorative side first to avoid chipping and damage. Hand Fabricating Drilling high speed drill bit 60 cutting angle with 12 - 15 clearance or hole saw. Cutting 72-tooth circular saw with reinforced carborundum or carbide-tipped blade. STORAGE FiberLite FRP should be stored horizontally indoors on a contiguous flat surface. Protective film should remain on the panel until installation. Panels should never be stored on the floor or an outside wall. Optimum stor

age conditions are 60F 16C to 75F 24C and 35 to 55 relative humidity. PRECONDITIONING Prior to installing FiberLite FRP remove the packaging materials and allow the panels to acclimate to room temperature and humidity for at least 48 hours. Ideally the room temperature and humidity during acclimation and installation should be the same as the final operation conditions. PRODUCT LIMITATIONS FiberLite FRP is designed as an indoor decorative panel. It should never be exposed to extremely high or extremely low moisture conditions. FiberLite FRP is designed to be installed over a solid wall surface and should never be directly installed over studs concrete concrete block or non insulated exterior walls. FiberLite FRP should be installed between 60F 16C to 75F 24C and 35 to 55 relative humidity. Non-compliance with product limitations may affect future performance and voids warranty. CLEANING INSTRUCTIONS FiberLite FRP is easy to clean. In most cases use a clean damp non-abrasive cotton cloth and a mild liquid detergent or household cleaner. Always rinse with clean water and a clean non-abrasive cotton cloth. Dry the panels with a soft clean non-abrasive cotton cloth. DO NOT USE abrasive cleaners with bleach cleaners with acid alkali or sodium hypochlorite. They will damage and permanently discolor the surface. Be sure that bottles rags or other materials with these cleaners never come in contact with the surface. Examples of harsh cleaners to avoid include but are not limited to Bleach Drain Cleaners Metal Cleaners Over Cleaners Rust Removers Tub and Tile Cleaners Lime Scale Remover REMOVAL OF STAINS To remove stains use full strength Fantastik All Purpose Cleaner Formula 409 Pine-Sol or other mild household cleaners. Blot with clean damp non-abrasive cotton cloth and rinse with cleaner water. When recommended cleaner changes its formulation the change may be harmful to the surface. Nudo Products Inc. cannot be held responsible for these changes. Follow all directions an

d warnings on the cleaner label because many are extremely flammable. Dyes and pharmaceutical products will permanently stain the panels. These include hair dyes and rinses silver nitrate laundry bluing tannic acid povidone-iodine dermatological tar compounds and peroxide. To reduce these stains apply a paste of baking soda and water on the area to pull out the stain. Do not rub as the paste will be slightly abrasive. Wipe up the past with a clean damp nonabrasive cotton cloth and rinse with clean water. Stains that are stubborn or even permanent and may not disappear include wood stains cash register inks newsprint marking pen inks indelible ink food pricing ink and label inks. Stubborn stains that may disappear on their own after a short time or after repeated cleaning include food stains glass rings water marks coffee and tea stains. FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS The numerical flame spread and smoke development ratings are not intended to reflect hazards presented by Nudo Product Inc. products or any other material under actual fire conditions. These rating are determined by small-scale tests conducted by Underwriters Laboratories and other independent testing facilities using the American Society for Testing and Materials E-84 test standards commonly referred to as the Tunnel-Test. NUDO PRODUCTS INC PROVIDES THESE RATING FOR MATERIAL COMPARISION PURPOSES ONLY. Like other organic building materials e.g. wood panels made up of composite material will burn. When ignited it may produce dense smoke very rapidly. All smoke is toxic. Fire safety requires proper design of facilities and fire suppression systems as well as precautions during construction and occupancy. Local codes insurance requirements and any special needs of the product user will determine the correct fire-rated interior finish and fire suppression system necessary for a specific installation. We believe all information given is accurate. It is offered in good faith but without guarantee.

Since conditions of use are beyond our control the user assumes all risks. Nothing herein shall be construed as a recommendation for use that infringes on valid patent or as extending a license under valid permit. Form 3004N.C Rev. 11 813 NUDO FiberLite FRP Technical Data 3004N.A _____________________________________________________________ Rev. 11 813 NUDO FiberLite FRP Class A Embossed and Smooth Wall Ceiling Panels NUDO FiberLite FRP panels are solid sheets composed of fiberglass and calcium carbonatefilled polyester resin. An embossed panel designed for interior wall finishes where washable durable panels are needed. NUDO FiberLite FRP is a durable flexible building wall material that is resistant to mold mildew and corrosion. The panel has a Class A rating for flame spread and smoke development when tested per ASTM E-84. Physical Properties Table 1 Typical Value Property Flexural Strength Flexural Modulus Tensile Strength Tensile Modulus Elongation Water Absorption Izod Impact Coefficient of Linear Thermal Expansion Barcol Hardness Specific Gravity Abrasive Resistance Flash Ignition Temperature Self Ignition Temperature Flame Spread Index Smoke Generation Surface Burn Test .09 Measure 10000 5 3.1 x 10 7000 5 3.1x 10 1.80 0.72 7.16 2.39 x 10 -5 35 1.5743 0.391 400 430 25 450 Class A Physical Properties Table 2 Part Number Nominal Panel Identifier Thickness Test Method psi psi psi psi 72 hrs 21C Ft-lbsin ASTM D790 ASTM D790 ASTM D638 ASTM D638 ASTM D638 ASTM D570 ASTM D256 50 Humidity Temp -23C ASTM D696 Average NA weight loss Fahrenheit Fahrenheit Unit NA Unit NA Class A ASTM D2583 ASTM D792 TABER ASTM D1929 ASTM D1929 ASTM E84 ASTM E84 ASTM E84 Nominal Panel Weight Color Size .090 .65 psf Almond Beige Ivory Pearl White Silver 4 x 8 10 Non-standard sizes available made-to-order. .090 .65 psf Almond Beige Ivory Pearl White Silver 2x2 4 LP-SR9 Smooth .090 .65 psf White 4 x 8 10 LP-SR9-CT Smooth .090 .65 psf White 2x2 4 LP-FR9 Embossed LP-FR9-CT Embossed

Form 3004N.A Rev. 11 813 SPECIFICATIONS The NUDO FiberLite FRP panels are manufactured with state-of-the-art laminating equipment and adhesives. COMPOSITION 1. Fiberglass and calcium carbonate-filled polyester resin. FINISHED PANEL QUALITY 1. 2. 3. 4. 5. 5. The front side shall be embossed with a pebble type finish embossed finished or the panels shall have a wear side with a smooth finish smooth. Colors shall be throughout the panel and manufactured as specified. The backside shall be smooth. Backside imperfections which do not affect functional properties are not cause for rejection. Physical properties shall be set forth in Table 1. Product quality standards and tolerance for panel weight and thickness shall be set for in Nudo Product Inc. Quality Control ProceduresStandards which are available upon request. Dimensions shall be specified on purchased order subject to the following tolerances Width 18 3.2mm Length 18 3.2 mm Squareness not more than 18 3.2 mm out of square. Panels shall be installed in accordance with the manufacturers guidelines as set forth in the installation guide. CERTIFICATION 1. Meets the minimum requirements of the major model building codes for Class A interior wall finishes. Flame spread of less than 25 smoke development less than 450 per ASTM E-84. FABRICATING RECOMMENDATIONS Note Protect your eyes with goggles cover your nose and mouth with a filter mask when cutting FiberLite FRP panels. When cutting FiberLite FRP position the panel so that the saw blade enters the decorative side first to avoid chipping and damage. Hand Fabricating Drilling high speed drill bit 60 cutting angle with 12 - 15 clearance or hole saw. Cutting 72-tooth circular saw with reinforced carborundum or carbide-tipped blade. STORAGE FiberLite FRP should be stored horizontally indoors on a contiguous flat surface. Protective film should remain on the panel until installation. Panels should never be stored on the floor or an outside wall. Optimum storage conditions

are 60F 16C to 75F 24C and 35 to 55 relative humidity. PRECONDITIONING Prior to installing FiberLite FRP remove the packaging materials and allow the panels to acclimate to room temperature and humidity for at least 48 hours. Ideally the room temperature and humidity during acclimation and installation should be the same as the final operation conditions. PRODUCT LIMITATIONS FiberLite FRP is designed as an indoor decorative panel. It should never be exposed to extremely high or extremely low moisture conditions. FiberLite FRP is designed to be installed over a solid wall surface and should never be directly installed over studs concrete concrete block or non insulated exterior walls. FiberLite FRP should be installed between 60F 16C to 75F 24C and 35 to 55 relative humidity. Non-compliance with product limitations may affect future performance and voids warranty. CLEANING INSTRUCTIONS FiberLite FRP is easy to clean. In most cases use a clean damp non-abrasive cotton cloth and a mild liquid detergent or household cleaner. Always rinse with clean water and a clean non-abrasive cotton cloth. Dry the panels with a soft clean non-abrasive cotton cloth. DO NOT USE abrasive cleaners with bleach cleaners with acid alkali or sodium hypochlorite. They will damage and permanently discolor the surface. Be sure that bottles rags or other materials with these cleaners never come in contact with the surface. Examples of harsh cleaners to avoid include but are not limited to Bleach Drain Cleaners Metal Cleaners Over Cleaners Rust Removers Tub and Tile Cleaners Lime Scale Remover REMOVAL OF STAINS To remove stains use full strength Fantastik All Purpose Cleaner Formula 409 Pine-Sol or other mild household cleaners. Blot with clean damp non-abrasive cotton cloth and rinse with cleaner water. When recommended cleaner changes its formulation the change may be harmful to the surface. Nudo Products Inc. cannot be held responsible for these changes. Follow all directions and warnings on

the cleaner label because many are extremely flammable. Dyes and pharmaceutical products will permanently stain the panels. These include hair dyes and rinses silver nitrate laundry bluing tannic acid povidone-iodine dermatological tar compounds and peroxide. To reduce these stains apply a paste of baking soda and water on the area to pull out the stain. Do not rub as the paste will be slightly abrasive. Wipe up the past with a clean damp nonabrasive cotton cloth and rinse with clean water. Stains that are stubborn or even permanent and may not disappear include wood stains cash register inks newsprint marking pen inks indelible ink food pricing ink and label inks. Stubborn stains that may disappear on their own after a short time or after repeated cleaning include food stains glass rings water marks coffee and tea stains. FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS The numerical flame spread and smoke development ratings are not intended to reflect hazards presented by Nudo Product Inc. products or any other material under actual fire conditions. These rating are determined by small-scale tests conducted by Underwriters Laboratories and other independent testing facilities using the American Society for Testing and Materials E-84 test standards commonly referred to as the Tunnel-Test. NUDO PRODUCTS INC PROVIDES THESE RATING FOR MATERIAL COMPARISION PURPOSES ONLY. Like other organic building materials e.g. wood panels made up of composite material will burn. When ignited it may produce dense smoke very rapidly. All smoke is toxic. Fire safety requires proper design of facilities and fire suppression systems as well as precautions during construction and occupancy. Local codes insurance requirements and any special needs of the product user will determine the correct fire-rated interior finish and fire suppression system necessary for a specific installation. We believe all information given is accurate. It is offered in good faith but without guarantee. Since conditi

ons of use are beyond our control the user assumes all risks. Nothing herein shall be construed as a recommendation for use that infringes on valid patent or as extending a license under valid permit. Form 3004N.A Rev. 11 813